Runlin foundation pit automation monitoring utilizes various advanced sensors and monitoring equipment to conduct comprehensive real-time automatic monitoring of key indicators such as deformation, horizontal displacement of walls (soil), groundwater level, support axial force, surface settlement, and settlement of surrounding buildings during the foundation pit construction process.
This system integrates cutting-edge technologies such as cloud computing and big data to build an online monitoring system for foundation pits. Its significant advantage lies in its ability to effectively resist adverse weather interference, achieve uninterrupted data collection and transmission, support users to view data in real time, greatly avoid errors caused by human factors, and ensure data stability and reliability.
Through this system, staff can timely and accurately grasp the operation status of foundation pits, issue warning signals for potential disasters in advance, and quickly activate emergency alarm mechanisms for sudden events, thereby significantly reducing the significant loss of life and property that may be caused by foundation pit accidents and avoiding the negative social impact. At the same time, based on in-depth analysis of monitoring data, provide scientific and solid basis for construction safety management and foundation pit design.
monitoring content | Monitored Parameters | MONITORING EQUIPMENT | Monitoring location |
Deformation monitoring | Horizontal displacement at the top of the enclosure wall | Total station | Top of enclosure wall |
Vertical displacement at the top of the enclosure wall | Total station and level | Top of enclosure wall | |
Deep horizontal displacement | Inclinometer | Enclosure structure and surrounding soil | |
Vertical displacement of column | Total station and level | Foundation pit pillar | |
Stress/strain monitoring | Supporting internal forces | Strain gauges, axial force gauges | Excavation support beam |
Internal force of column | Reinforcement meter | Foundation pit steel column | |
Internal force of anchor rod | Anchor cable meter | Surrounding the foundation pit | |
Internal force of soil mass | Reinforcement meter | Surrounding the foundation pit | |
Internal force of enclosure wall | Reinforcement meter | Excavation enclosure wall | |
Surrounding environment monitoring | Vertical displacement of surrounding ground surface | Total station | Surrounding surface |
Vertical displacement of surrounding buildings | Static level | Surrounding buildings | |
Surrounding buildings tilted | Inclinometer | Surrounding buildings | |
Horizontal displacement of surrounding buildings | Total station | Surrounding buildings | |
Surrounding buildings and surface cracks | crackmeter | Surrounding buildings and surfaces | |
Deformation of surrounding pipelines | Total station | Surrounding pipelines | |
groundwater level | Pore water pressure gauge, liquid level gauge | Surrounding the foundation pit |